MAICO

OAE Test System

Results in 7 seconds

Handheld, with no cables

Printouts in 3 seconds

Immediate pass / refer results

Reimbursable / economical

In-office training included

ERO•SCAN

Performs screening and

diagnostic OAE

 

List Price: $3420.00 #586

Routine Uses:

• Screen infants in the newborn nursery.

• Performs follow-up hearing testing on infants from

the nursery screening, and at well-baby checks.

• Obtain objective hearing test results from both ears of toddlers.

• Identify and monitor middle ear pathology (e.g. otitis media).

• Assess cochlear function (without the need for a behavioral response) following the insertion of pressureequalization

(PE) tubes.

• Monitor hearing in children at-risk for progressive hearing loss.

• Screen patients of all ages for cochlear (sensory) function so that appropriate recommendations for

amplification can be made.

Differential Diagnosis:

• Differentiate cochlear from retrocochlear pathology when used in combination with auditory brainstem

response (ABR).

• Observe changes in cochlear function during episodes of Méniére’s Disease.

• Confirm suspected non-organic hearing loss (malingering).

• Monitor the effects of ototoxic medications. OAEs will often be abnormal before audiometric changes are noted.

• Detect early signs of hearing loss from noise exposure (musicians, factory workers, others).

• Recognize auditory neuropathy. The presence of normal OAEs and abnormal ABR findings distinguishes

this low-incidence disorder.

ERO•SCAN and accessories

 

ONE YEAR LIMITED WARRANTY: This warranty is extended to the original purchaser of the instrument, by Maico, through the Distributor from whom it was purchased. The warranty covers defects in material and workmanship for a period of one year from

date of delivery of the instrument to the original purchaser. Accessories which are purchased from Maico at the same time as the instrument are warranted for one year from the date of purchase. For additional information contact your Maico Distributor.

Technical Data

PROBE

Measurement Type . . . . . . .Otoacoustic Emissions (OAE)

Frequency Range . . . . . . . .1.5 to 6 kHz (2 to 4 kHz

default)

Stimulus Intensity Range . .40 to 65 dB SPL

Maximum Output

(protection) . . . . . . . . . .90 dB SPL

Microphone System Noise .-20 dB SPL @ 2 kHz

(1 Hz bandwidth)

Stimulus Sampling Rate . . .31,250 Hz

Averaging Time . . . . . . . . .0.5, 1, 2, or 4 seconds

Artifact Rejections . . . . . . .Unit will correctly measure

strong OAEs in speech

babble background noise

of 65 dBA

INSTRUMENT

Power Supply . . . . . . . . . . .(4) AA cells – alkaline

(6V Total)

Battery Life . . . . . . . . . . . .Approximately 300 tests

Instrument Weight . . . . . . .10.6 oz. (300g) including

batteries

PRINTER

Type . . . . . . . . . . . . .Thermal dot matrix line printer

Speed . . . . . . . . . . . .>10 lines per second

Operating Noise . . .<50 dB SPL

Weight . . . . . . . . . . . .1.4 lbs. (630g) including battery pack

Paper . . . . . . . . . . . .Thermal roll – 2.25” wide

POWER SUPPLY

Ni-Cad rechargeable battery pack

Battery Pack Recharger . . .Plug-In transformer 12 V

400 mA 120 V doubleinsulated

UL544

Battery Life . . . . . . . . . . . .Approximately 300 tests

PROCESSOR

Digital Signal Processor . . . .Motorola 56303 24-bit

66 MHz 3.3V

Storage . . . . . . . . . . . . . . . .1 MB flash EEPROM

(non-volatile)

Battery Backup . . . . . . . . .0. 1F 5.0V (approx. 24 hours)

CODEC . . . . . . . . . . . . . . .18 bit D/A, 18 bit A/D

96 dB SNR typical

Display . . . . . . . . . . . . . . . .4 line x 10 character STN

liquid crystal

SWITCHES

Membrane keypad . . . . . . . . .1 million + actuation

Accessories

Part Number Part

586-5 . . . . . . . . . . . . . . . . .cradle

586-9 . . . . . . . . . . . . . . . . .printer

586-3 . . . . . . . . . . . . . . . . .printer cable

586-8 . . . . . . . . . . . . . . . . .thermal printer paper

586-6 . . . . . . . . . . . . . . . . .headphones

586-2 . . . . . . . . . . . . . . . . .probe tips

1162-9925 . . . . . . . . . . . . . .user manual

586-7 . . . . . . . . . . . . . . . . .carrying case

586-3 . . . . . . . . . . . . . . . . .power supply

CPT Codes

92587 . . . . . . . . . . . . . . . . .Evoked OAE; limited

92588 . . . . . . . . . . . . . . . . .Diagnostic OAE

Specifications subject to change without notice

ERO•SCAN 6/00

 

New Visitor Registration
Previous Visitor Sign In
Search  ||  Site Map  ||  Home  ||  E-Mail Us || Top of Page
BusinessOL