List
Price: $3420.00 #586 |
Routine
Uses:
• Screen infants in the newborn
nursery.
• Performs follow-up hearing
testing on infants from
the nursery screening, and at well-baby checks.
• Obtain objective hearing test
results from both ears of toddlers.
• Identify and monitor middle
ear pathology (e.g. otitis media).
• Assess cochlear function (without
the need for a behavioral response) following the insertion of pressureequalization
(PE) tubes.
• Monitor hearing in children
at-risk for progressive hearing loss.
• Screen patients of all ages
for cochlear (sensory) function so that appropriate recommendations
for
amplification can be made.
Differential
Diagnosis:
• Differentiate cochlear from
retrocochlear pathology when used in combination with auditory
brainstem
response (ABR).
• Observe changes in cochlear
function during episodes of Méniére’s Disease.
• Confirm suspected non-organic
hearing loss (malingering).
• Monitor the effects of ototoxic medications. OAEs will
often be abnormal before audiometric changes are noted.
• Detect early signs of hearing
loss from noise exposure (musicians, factory workers, others).
• Recognize auditory neuropathy.
The presence of normal OAEs and abnormal ABR
findings distinguishes
this low-incidence disorder.
ERO•SCAN
and accessories
ONE YEAR LIMITED WARRANTY: This warranty is extended to the original purchaser of the instrument,
by Maico, through the Distributor from whom it was
purchased. The warranty covers defects in material and workmanship
for a period of one year from
date of delivery of the instrument to the original purchaser. Accessories
which are purchased from Maico at the
same time as the instrument are warranted for one year from the date of purchase.
For additional information contact your Maico
Distributor. |
|
Technical
Data
PROBE
Measurement
Type . . . . .
. .Otoacoustic Emissions (OAE)
Frequency
Range . . . . .
. . .1.5 to 6 kHz (2 to 4 kHz
default)
Stimulus Intensity Range . .40 to 65 dB SPL
Maximum
Output
(protection) . . . . . . . . . .90 dB SPL
Microphone
System Noise .-20 dB SPL @ 2 kHz
(1
Hz bandwidth)
Stimulus
Sampling Rate .
. .31,250 Hz
Averaging
Time . . . . .
. . . .0.5, 1, 2, or 4 seconds
Artifact
Rejections . .
. . . . .Unit will correctly measure
strong OAEs in speech
babble background noise
of 65 dBA
INSTRUMENT
Power
Supply . . . . . . . . . . .(4)
AA cells – alkaline
(6V
Total)
Battery
Life . . . . . . . . . . . .Approximately
300 tests
Instrument
Weight . . . .
. . .10.6 oz. (300g) including
batteries
PRINTER
Type
. . . . . . . . . . . . .Thermal
dot matrix line printer
Speed
. . . . . . . . . . . .>10 lines per second
Operating
Noise . . .<50 dB SPL
Weight
. . . . . . . . . . . .1.4
lbs. (630g) including battery pack
Paper
. . . . . . . . . . . .Thermal
roll – 2.25” wide
POWER
SUPPLY
Ni-Cad
rechargeable battery pack
Battery
Pack Recharger . . .Plug-In transformer 12 V
400
mA 120 V doubleinsulated
UL544
Battery
Life . . . . . . . . . . . .Approximately
300 tests
PROCESSOR
Digital
Signal Processor .
. . .Motorola 56303 24-bit
66
MHz 3.3V
Storage
. . . . . . . . . . . . . . . .1 MB flash
EEPROM
(non-volatile)
Battery Backup . . . . . . . . .0. 1F 5.0V (approx. 24 hours)
CODEC
. . . . . . . . . . . . . . .18 bit D/A, 18 bit A/D
96
dB SNR typical
Display
. . . . . . . . . . . . . . . .4 line x 10
character STN
liquid crystal
SWITCHES
Membrane
keypad . . . .
. . . . .1 million + actuation
Accessories
Part
Number Part
586-5
. . . . . . . . . . . . . . . . .cradle
586-9
. . . . . . . . . . . . . . . . .printer
586-3
. . . . . . . . . . . . . . . . .printer cable
586-8
. . . . . . . . . . . . . . . . .thermal printer
paper
586-6
. . . . . . . . . . . . . . . . .headphones
586-2
. . . . . . . . . . . . . . . . .probe tips
1162-9925
. . . . . . . . . . . . . .user manual
586-7
. . . . . . . . . . . . . . . . .carrying case
586-3
. . . . . . . . . . . . . . . . .power supply
CPT
Codes
92587
. . . . . . . . . . . . . . . . .Evoked OAE;
limited
92588
. . . . . . . . . . . . . . . . .Diagnostic
OAE
Specifications
subject to change without notice
ERO•SCAN 6/00 |